We are engaged in manufacturing and supplying Ampere Hour Meters and Ampere Minute meters for a wide range of applications for precision electroplating and battery testing applications.
Electroplating: Plating thickness is directly proportional to the integration of current over a period of time. The preset Amp-Hr or Amp-Min limit ensures precision repeatability and uniformity of the plating thickness guaranteeing quality and avoiding wastage of material. Time controlled dosage pumps allow automation. Hence where there is a criticality of thickness of plating and uniformity is required, Ampere Hour/Minute Meter is the solution. For example, gold plating, rhodium plating, platinum plating etc.
Battery Testing: The instrument integrates the current while allowing the charged battery to discharge through a load until the battery voltage falls below the specified limit (10.5V for a 12V battery), to give a measure of the AH rating of the battery.
Product Details:
Type | Digital |
Usage/Application | Industrial |
Brand | Countronics |
Material | ABS |
Color | Black |
Operating Temperature | 50 Degree Celsius |
Packaging Type | Box |
Country of Origin | Made in India |
Product Details:
Usage/Application | Industrial |
Brand | Selec |
Application | Industrial |
Usage | Industrial |
Power Frequency | DIGITAL AMP HOUR METER |
Categories | DIGITAL AMP HOUR METER |
Features | DIGITAL AMP HOUR METER |
Operation Mode | DIGITAL AMP HOUR METER |
Accuracy | DIGITAL AMP HOUR METER |
Display | :All of 0.56in character height Red 7 Segment displays a.3 Digits to display voltage 0 – 99.9V b.4 Digits to display current 0 – 999.9Amps c.6 Digits to display Amp-Hour (4 Digit) and cumulative Amp-Hour (6 Digit) |
Max. Shunt | : Max. value of 999.9 Amps corresponding to 75mV. User programmable from front in ‘CAL’ mode. (Max. value of 9999Amps also available on request) |
Selection of Amp Hour/Min | : Short Pin 17-18 for Amp-Hour Open link of Pin 17-18 for Amp-Minute |
0.1AH/Amin | : Higher 0.1 resolution by shifting internal jumper by opening cover |
Totaliser | : 6 Digit readable in ‘Total’ Mode |
Limit | Up to 9999 Ahr/Amin settable in limit mode using increment/decrement switches |
Relay | : NO-P-NC of 5 Amp at 220V AC contact rating |
Start | : Pressing front panel switch or momentarily shorting rear Pins 5 & 6 by wiring an external switch |
Memory | :Non-volatile EEPROM solid state memory Stores programmed value of shunt, preset value, current Amp-Hr and the current Cumulative Amp-Hr to preserve current status on power failure |
Lock | : Open Link between Pin 1 & 2 to Lock ‘Cal’ i.e. shunt value |
Low Voltage Stop | Internally set at 10.5V for testing 12V battery. Short Pins 3 & 4 for this function |
Supply | : 220V AC ± 10% at 50/60Hz |
Size | : Vertical type with front panel 96 x 192 mm |
Terminals | : At rear with marking for wiring |
Mounting | : Panel Mounted |
Fuse | : At rear of 0.2Amps |
Product Details:
Type | Digital |
Usage/Application | Industrial |
Model Name/Number | 800AH |
Brand | Countronics |
Material | Plastic ABS |
Color | Black |
Operating Temperature | 50 Degree Temperature |
Packaging Type | Box |
Country of Origin | Made in India |
Model-800AH
We offer model 800AH programmable amp-hour meter, that is used for electroplating thickness control and testing battery Amp-Hr. These meters are available with 6 RED 7 Segment LEDs of 0.56” character height. However, the current display is fixed at Max 9999 Amps using a shunt of current & 75mV for user programmed. Following are some of the features of our model 800AH programmable amp-hour meter:
Shunt calibration programmable
Stores cumulative Amp-Hour
Instantaneous current display
Settable Limit for Amp-Hr/Min
Front membrane switches for easy operation
Non-volatile memory for storing settings, hence no battery required
Further, our Model 800AH Programmable Amp-Hour Meter has below mentioned technical specifications:
Amp-Hour: Max 9999 A-H for each preset cycle. (Amp-Hour range is selected by shorting Pin 17-18 at the rear)
Amp-Minute: Max 9999 A-Min for each preset cycle. (Amp-Minute is selected, opening the link between Pin 17 & 18).
Max shunt: Max value of 9999 Amp corresponding to 75mV
Totalize: 6 Digits for Amp-Hour or Amp-Min. i.e. 99, 99, 99. (readable for 10 sec by going into ‘total’ mode)
Limit: Up to 9999 AH or Amin. Setting (In limit mode using incr. & decr. switches).
Relay Contact: One NO-P-NC of 5 Amp rating.
Trigger start: By pressing front panel switch or closing a rear external contact.
Battery Back-Up: Not required. Programmed values & readings, including A-H stored in EEPROM.
Lock: Electronic lock for calibration (open link between Pin 1 & 2 to lock CAL) Low Volt.
Trigger: Set at 10.5V internally, for testing 12V Battery AH. (With Pin 3 & 4 shorted)
Increased Res.: 0.1AH or 0.1AMin facility by shifting internal jumper
Supply: 220V AC 10%
Size: Front Fascia 96 mm x 96 mm, Depth 135 mm, Cut Out: 91 mm x 91 mm.
Weight: 800 grams
Product Details:
Usage/Application | Industrial |
Brand | Trumeter Usa |
Shunt Value Programmable At | AMPERE HOUR METERS |
Totalizer Display | AMPERE HOUR METERS |
Model Number/Name | AMPERE HOUR METERS |
Dimension | AMPERE HOUR METERS |
Display For Totalizer | AMPERE HOUR METERS |
Usage | Industrial |
Ampere-Hour/Minute Meter With Dual Time Relays
Model-804AH
We are engaged in manufacturing Ampere-Hour & Minute Meters Model 804AH, that are designed and developed aesthetically with membrane switches for the front panel. These are offered with shunt calibration programmable of up to 9999 for 75 mV. We also offer separate displays for current and ampere-hours per min. Following are some of the features and specifications of our Ampere-Hour & Minute Meter Model 804AH:
Ampere-Hour/Minute selectable
Cumulative Ampere-Hour stored on power failure
Settable limit for Ampere-Hours
Dual time relays with on time settable
Rear calibration lock to prevent tampering with settings
Specifications:
Display |
|
Shunt Calibration |
|
Set Point |
|
Resolution |
|
Totaliser |
|
Time Relays |
|
Contact Rating |
|
Memory |
|
Lock |
|
Supply |
|
Size |
|
Weight |
|
Product Details:
Usage/Application | Industrial |
Size | PROGRAMMABLE AMPERE HOUR METER |
Phase | PROGRAMMABLE AMPERE HOUR METER |
Display Type | PROGRAMMABLE AMPERE HOUR METER |
Brand | PROGRAMMABLE AMPERE HOUR METER |
Shunt Value Programmable At | PROGRAMMABLE AMPERE HOUR METER |
Totalizer Display | PROGRAMMABLE AMPERE HOUR METER |
Dimension | PROGRAMMABLE AMPERE HOUR METER |
Display | 4 Digit 7 Segment Red LED display for Ampere |
Shunt Calibration | Maximum 9999 Amps corresponding to 75mV |
Set Limit | Settable from 0-9999 |
Resolution | 1AH/1AM |
Time Relay | Relay contact with time settings in Mins:Secs |
Contact Rating | NO-P-NC @ 5Amps/220V AC |
Memory EEPROM | Settings and Ampere-Hours saved in solid state |
Lock with shunt settings | By rear jumper to prevent accidental tampering |
Supply | 220V AC ± 10% @ 50/60Hz |
Size | Front Fascia 96mm x 99mm Depth 135mm. Cut Out : 91mm x 91mm. |
Weight | 800 grams |