Ampere Hour Meters pH And ORP Indicators and Controllers Combined pH/ORP/Conductivity/TDS Bench Top Indicator Digital pH Indicator, Panel Mounted pH/MV/Temp.Indicator Table/Bench Top Wall Mounted pH Indicator PH Controller With Dual Limits And Isolated 4-20ma Tx. Output PH Controller With Control Output And Window Alarm Output And Iso. Tx Ph Controller With Dual Control Limits And Dual Alarms & Isolated Transmitter ORP Controller With Dual Control Limits and Dual Alarms and ISO. TX. Model 100-orp ORP Controller With Dual Control Limits And ISO. 4-20ma Tx.Output Combined pH And ORP Controller With Separate Limits For pH And ORP Humidity Indicators Conductivity Indicators Data Loggers Systems Flow Indicators and Controllers Peak Load Indicators Production Display Boards Calibrators Equipment Speed Indicators Digital Counters Digital Timers Temperature Indicators Process Indicators and Controllers Clean Room Monitor Digital ReadOut for Encoders Temperature Logger
 |
 |
 |
|
|
 |
| | Combined pH/ORP/Conductivity/TDS Bench Top Indicator Model 5501 -
Accurate pH display with 0.01pH resolution -
Auto buffer recognition with 2 point calibration for pH -
Auto/Manual temperature compensation selectable for both pH and Conductivity -
4 Step Range selection 0.1µs to 199.9ms for conductivity -
Cell Factor selectable for both 1.0 and 0.1 -
Digital calibration for conductivity -
Auto Temp Compensation using PT100 sensor -
One touch switching between conductivity and pH display selections -
Large alphanumeric LCD display with bright back light -
Aesthetically designed front panel with membrane switches and sleek bench top cabinet Specification
| Display | 2 line large alphanumeric display with back light illumination | | Ranges | pH: 0.00 to 14.00 pH ORP: 0-2000mV Conductivity:19.99ms/1999µs/199.9µs/19.99µs in 0.1
Cell Constant 199.9ms/19.99ms/1999µs/199.9µs in 1.0 Cell Constant
TDS: 0-1999ppm | | Resolution | pH: 0.01pH ORP: 1mV
Conductivity: 0.01ms or 0.01µs depending on range & Cell factor
TDS: 1ppm | | Auto Temp. Comp. | 0-1000C using PT100 external sensor for pH and Conductivity | | Manual Temp. Comp. | Settable from front panel from 0-100.0°C for pH and Conductivity | | pH Calibration | 2 Point calibration with auto buffer recognition. Buffers recognized: 4.00, 7.00, 9.00, 10.00 pH | | Conductivity Calibration | Digital calibration by factor multiplication from 0.75-1.25 | | Accuracy | 0.5% ± 1 Digit | | Supply | 220V AC ±10% 50Hz |
| 
| |
|
 |
|
|
|
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
 |
 |
|
 |
 |
 |
|
|
 |
| | ORP Controller With Dual Control Limits And ISO. 4-20ma Tx.Output Model 110-ORP
- Model 110 ORP controller is panel mounted DIN size instrument with 3½ Digit LCD.
-
Indicates the value of Oxidation-Reduction Potential (REDOX) when attached to an ORP electrode. -
User settable separate control limits and control outputs for Oxidation and reduction -
A consent contact input, at the rear, enables all control outputs. This consent input is the output of a pH controller. The equipment also provides an isolated 4 to 20mA output for recorder purpose. Specifications: | Display | : 3½ Digit LCD 12.5 mm | | Range | : ± 1999 mV | | Set Limits | : 0-1999 mV for OXID/REDUC |
|
| | Accuracy | : 0.5% ± 1 Digit | | Input Impedence | : > 10¹² Ohms | | Relay Outputs | : 110V/220V AC 5 Amp. | | Transmitter Output | : 4-20 mA Isolated for 0-1000 mV | | Calibration Zero Adjust | : RANGE ± 30 mV | | Consent Contact Input | : From pH CONTROLLER. If open , cuts off all Relay Outputs. | | Supply | :110/220V AC ± 10% | | Control Logic | : REDUC : ORP > SET LIMIT. REDUC RELAY ON. | | | : OXID : ORP < SET LIMIT. OXID RELAY ON. | | Size | : 96x96x141mm | | Shipping Weight | : 1000 grms. |
|
| |
|
 |
|
|
|
 |
|
 |
|