Ampere Hour Meters pH And ORP Indicators and Controllers Humidity Indicators Conductivity Indicators Data Loggers Systems Flow Indicators and Controllers Peak Load Indicators Peak Load Indicator Logger With Pace Rate Indication For CTMs Peak Load Indicator With Internal Peak Recording For CTMs Peak Load And Displacement Recording Indicator For UTMs Digital Load And Displacement Logger With Rs-232 Or Direct Printer Output Production Display Boards Calibrators Equipment Speed Indicators Digital Counters Digital Timers Temperature Indicators Process Indicators and Controllers Clean Room Monitor Digital ReadOut for Encoders Temperature Logger
 |
 |
|
 |
 |
 |
|
|
 |
 |
| | 
 | Peak Load Indicator With Internal Peak Recording For CTMs Model CT901 - Separate displays for load indication and maximum range
- Range for load indication corresponding to 4-20mA input digitally settable from front panel
- Peak/Normal mode selectable
- Up to 9 peaks can be recorded and recalled
- Buzzer annunciation at Peak
- Relay output for load limit detection with limit digitally settable
- Digital tare provided to remove initial error
- Non-volatile memory for saving configuration
- Configuration lock at rear to prevent tampering with Range
- Aesthetically designed front panel with membrane switches
Specification : | Display | 4 Digit 0.56” 7 segment Red LED display for Load (KN) 4 Digit 0.56” 7 segment Red LED display for Set Point (KN) | | Range | Load: 1KN to Range Displacement: 0.1mm to 9999 | | Accuracy | ±0.1% of Full Scale ± 1 digit | | Input | From 2 wire loop transmitter giving 4-20mA output 4-20mA input => 0 - Range | | Relay Logic | When Actual Load ≥ Set Load Limit relay switches On. | | Normal/Peak Mode | Selectable from front panel with LED indication of mode | | Peak Read | Last 9 peaks can be recalled with facility to reset memory | | Peak Detection | Peak hold resettable by front Reset Switch or by parallel rear external contact | | Tare Facility (Zero) | Digital Tare using front panel Tare switch up to a maximum of 50KN (for removing initial offset error) | | Memory | Non-volatile EEPROM to save settings | | Configuration Lock | On rear terminals to prevent unauthorized/accidental alteration of Range using front switches | | Supply | 220V AC ± 15% 50/60Hz | | Dimensions | Front Fascia: 96mm x 192mm Cut Out : 92mm x 188mm |
| | |
|
 |
|
|
|
|
 |
|
 |
 |
|
 |
 |
 |
|
|
 |
 |
| |
 | Digital Load And Displacement Logger With Rs-232 Or Direct Printer Output Features : -
Load & Displacement Indication for Universal Testing Machines -
Large alphanumeric LCD display with backlight -
Direct Thermal Printer or RS-232 output for PC selectable for storing time stamped Load and Displacement values -
Direct display of instantaneous Pace rate -
Sample Area digitally settable -
Peak Stress displayed on peak detection -
Internal Real Time Clock with battery backup -
Peak/Normal mode selectable -
Buzzer alarm for peak detection in Peak Mode -
Relay output for over load and over carry detection -
Digital tare provided -
Non-volatile memory for saving configuration -
Configuration Lock by Password -
Aesthetically designed front panel with membrane switches Specification :
| Display | 2 Line alphanumeric display with back light illumination | | Range | Load - 0.1KN to 5000.0KN Displacement – 0.001 to 9999.9 mm Set Load (Limit) - 0.1KN to 5000.0KN Set Displacement – 0 to 5000.0 mm Sample Area - 0.1cm2 to 600.00cm2 Stress – 1 to 5000 KN/cm2 | | Accuracy | ±0.1% of Full Scale ± 1 digit | | Input | From 2 wire loop transmitter giving 4-20mA output 4-20mA input => 0 - Range | | Relay Logic | ON when Load ≥ Set Load Limit OR Displacement ≥ Set Displacement. | | Normal/Peak Mode | Selectable from front panel with indication on LCD | | Real Time Clock | Internal RTC with rechargeable Ni-Cd. Battery backup | | Peak Detection | Buzzer alarm re-settable from front Reset switch | | Tare Facility (Zero) | Digital Tare for Load and Displacement using front panel Tare switch | | Memory | Non-volatile EEPROM to save settings | | Configuration Lock | Digital Password lock to prevent alteration of Calibration | | Supply | 220V AC ± 15% @ 50/60Hz | | Dimensions | Front Panel: 96mm x 192mm Cut Out : 92mm x 188mm |
| | |
|
 |
|
|
|
|
|