 |
Ampere Hour Meters pH And ORP Indicators and Controllers Humidity Indicators Conductivity Indicators Data Loggers Systems Flow Indicators and Controllers Digital Flow Rate Indicator Cum Totalizer Digital Flow Rate Indicator Cum Totalizer With Dual Set Limits Digital Flow Rate Indicator Cum Totalizer For Both Analog And Digital Input Peak Load Indicators Production Display Boards Calibrators Equipment Speed Indicators Digital Counters Digital Timers Temperature Indicators Process Indicators and Controllers Clean Room Monitor Digital ReadOut for Encoders Temperature Logger
 |
 |
|
 |
 |
|
 |
 |
 |
|
|
 |
| | Digital Flow Rate Indicator Cum Totalizer For Both Analog And Digital Input Model 2502A -
4 digit display for Flow Rate -
6 digit display for integrated flow values -
Compatible with both Analog and Pulse output sensors -
Flow rate settable in Per Min OR Per Hour -
Linear or square root function selectable -
Span programmable with floating decimal point -
Totalised flow saved in memory on power failure -
Rear panel configuration lock -
Attractive ABS panel mounted cabinet Specification : | Display | 4 digit 0.56” 7 segment Red LED display for Flow Rate 6 digit 0.56” 7 segment Red LED display for Totaliser | | Sensor Type | a. Differential pressure transmitter (4-20mA or 0-20mA) b. Turbine type flow sensor (Pulsed Output) | | Input | 4-20mA, 0-20mA or Pulse Input (10 per min to 60,000 per min) | | Time Base | Per Minute/ Per Hour selectable | | Calibration | For Pulse Input - a. K-Factor of Turbine sensor : Range: 0.100 to 999.999 (K Factor = Volume/Pulse) For Analog Input - a. Linear/Square root function selectable b. For 4-20mA: Span settable from 000.0 to 9999 c. For 0-20mA: Span settable from 000.0 to 9999 | | Flow Rate | 0.001 to 9999 units per min Flow Rate = (Input pulses per min) * (Multiplier) | | Set Points | Range: 1 to 999999 with resolution depending upon the selected range for cumulative flow. Logic: Relay 1 ON for Integrated Flow > Set Point 1 Relay 2 ON for Integrated Flow > Set Point 2 5A/220V AC rating NO-P-NC contacts | | Memory | Totalised flow saved in EEPROM to prevent loss on power failure | | Totalized Flow | 0.001 to 999999 | | Totaliser Reset | By front panel touch switch | | Sensor Supply | Separate 10V supply for turbine sensor and pressure transmitter | | Configuration Lock | By rear jumper to prevent tampering with configuration | | Supply | 220V AC ± 15% 50/60Hz | | Dimensions | 96mm x 96mm x 135mm. Panel Cut Out: 91mm x 91mm | | Weight | 800 gram |
| 
| |
|
 |
|
|
|
|